Leak Rate Calculator (2024)

Register to enable "Calculate" button.

Water Leak from Hole in Copper Pipe (photograph)

Leak Rate Calculator (1)

Leak Rate Equations

Leak Rate Calculator (2)

Leak Rate
Leaks are common occurrences in pipes, tubes, and tanks. The leak rate is based on the pressure difference between the inside and outside of the pipe, the crack or hole area, and specific gravity of the liquid. The pipe leak rate calculator computes the leak rate of a liquid out of a circular or non-circular crack or hole in a pipe or tank. The leak rate calculation has built-in specific gravity values for water, seawater, diesel fuel, SAE 30 oil, and gasoline. Specific gravity can be entered for other liquids. If the leak rate is known, the calculator can compute pressure or crack area (and diameter).

Leak Rate Equations and Derivation

Liquid inside a pipe, tank, or other confined space flows out through a hole or crack. The liquid in the pipe is at an elevation Z1, has pressure P1, and has velocity V1. As the liquid exits the hole, it increases to velocity V2 through the hole, pressure P2 at the hole exit, and an elevation Z2 of the hole exit.

Diagram of liquid flowing out of pipe through crack:
Leak Rate Calculator (3)

The Bernoulli equation (Munson et al., 1998, p. 114; bernoulli.php) describes flow of an inviscid fluid flowing from location 1 to location 2.

Leak Rate Calculator (4)

Specific gravity S = ρ/ρw,std, the ratio of density of the flowing liquid to density of water at standard conditions (4oC), which is 1000 kg/m3.

The Bernoulli equation has many applications. Leak rate is one application where it is widely used. Since a pipe is usually much larger diameter than the hole, V2>>V1. Since the elevation change Z2-Z1 is typically very small compared to other terms in the Bernoulli equations for a pipe leak application, Z2-Z1=0. Thus:

Leak Rate Calculator (5)

Solve for V2:

Leak Rate Calculator (6)

Then with Q=V2A2, A=πd2 / 4, and ΔP=P1-P2:

Leak Rate Calculator (7)

Due to the viscosity of liquids and the tortuous path of the liquid through the hole, the measured leak rate from a hole is less that that computed by the above equation. To account for these effects, a discharge coefficient C is commonly used in the equation (e.g. Munson et al., 1998, p. 531; McAllister, 2005, p. 356):

Leak Rate Calculator (8)

C=0.61 is a typical value determined from experiments (McAllister, 2005, p. 356). Velocity out of the hole is computed approximately as:

Leak Rate Calculator (9)

A more accurate computation of velocity can be found using the methods at our Discharge from a Tank calculation which splits C into a velocity coefficient and a contraction coefficient. Our Bernoulli equation calculator applies the Bernoulli equation to many situations including pipe leak, but does not include a discharge coefficient.

Variables
The units shown for the variables are SI (International System of Units); however, the equations above are valid for any consistent set of units. Our calculation allows a variety of units; all unit conversions are accomplished internally.
A = Hole or crack area (m2).
C = Discharge coefficient. Need 0 < C ≤ 1. Suggested value is C=0.61 (McAllister, 2005, p. 356). For highly viscous liquids, C is lower.
d = Hole diameter (m).
g = Acceleration due to gravity, 9.8066 m/s2.
Q = Leak rate (m3/s).
S = Liquid specific gravity. In calculation, S for water is from Munson et al. (1998, p. B.2); seawater, SAE 30 oil, and gasoline are from Munson Table 1.6; and diesel is from Chevron (2007, p. 48).
V = Leak velocity (m/s).
ΔP = Pressure drop from inside of pipe to outside of pipe (or tank) (N/m2).
ρw,std = Mass density of water at standard conditions (4oC), 1000 kg/m3.
π = 3.1415926...

Error Messages given by calculation
"Need A > 0", "Need 0 < C ≤ 1", "Need d > 0", "Need S > 0", "Need Q > 0","Need ΔP > 0".

References
Chevron Corporation. 2007. Diesel Fuels Technical Review. Retrieved from https://www.chevron.com/-/media/chevron/operations/documents/diesel-fuel-tech-review.pdf

McAllister, E. W. (editor). 2005. Pipeline Rules of Thumb Handbook. Elsevier - Gulf Professional Publishing.

Munson, B.R., Young, D.F, and Okiishi, T. H. 1998. Fundamentals of Fluid Mechanics. John Wiley and Sons, Inc. 3ed.

© 2017-2024 LMNO Engineering, Research, and Software, Ltd. All rights reserved.

Please contact us for consulting or questions about pipe leak rate.

LMNO Engineering, Research, and Software, Ltd.
7860 Angel Ridge Rd. Athens, Ohio45701 USA Phone: (740) 707-2614
LMNO@LMNOeng.com https://www.LMNOeng.com

To:
LMNO Engineering home page (more calculations)

Related calculations:

Gas leak rate

Bernoulli applications

Time to drain a tank

Discharge from a tank (steady state)

Orifice flow meter in pipe for liquids (D<5cm)

Orifice flow meter in pipe for liquids (D5cm)


Other information:

Unit Conversions Calculator

Register

Leak Rate Calculator (2024)

References

Top Articles
Latest Posts
Recommended Articles
Article information

Author: Prof. An Powlowski

Last Updated:

Views: 5723

Rating: 4.3 / 5 (64 voted)

Reviews: 87% of readers found this page helpful

Author information

Name: Prof. An Powlowski

Birthday: 1992-09-29

Address: Apt. 994 8891 Orval Hill, Brittnyburgh, AZ 41023-0398

Phone: +26417467956738

Job: District Marketing Strategist

Hobby: Embroidery, Bodybuilding, Motor sports, Amateur radio, Wood carving, Whittling, Air sports

Introduction: My name is Prof. An Powlowski, I am a charming, helpful, attractive, good, graceful, thoughtful, vast person who loves writing and wants to share my knowledge and understanding with you.